| 51-CTC350120-10 | Climate Test Chamber 120 Liters (Temperature Range: -10°C / +60°C, Humidity Range: 20% to 95% Rh) - 220-240 V 50/60 Hz |
| 51-CTC350120-20 | Climate Test Chamber 120 Liters (Temperature Range: -20°C / +80°C, Humidity Range: 20% to 95% Rh) - 220-240 V 50/60 Hz |
| 51-CTC350120-40 | Climate Test Chamber 120 Liters (Temperature Range: -40°C / +60°C, Humidity Range: 20% to 95% Rh) - 220-240 V 50/60 Hz |
| 51-CTC350120-60 | Climate Test Chamber 120 Liters (Temperature Range: -60°C / +60°C, Humidity Range: 20% to 95% Rh) - 220-240 V 50/60 Hz |
| 51-CTC350250-10 | Climate Test Chamber 250 Liters (Temperature Range: -10°C / +60°C, Humidity Range: 20% to 95% Rh) - 220-240 V 50/60 Hz |
| 51-CTC350250-20 | Climate Test Chamber 250 Liters (Temperature Range: -20°C / +80°C, Humidity Range: 20% to 95% Rh) - 220-240 V 50/60 Hz |
| 51-CTC350250-40 | Climate Test Chamber 250 Liters (Temperature Range: -40°C / +60°C, Humidity Range: 20% to 95% Rh) - 220-240 V 50/60 Hz |
| 51-CTC350250-60 | Climate Test Chamber 250 Liters (Temperature Range: -60°C / +60°C, Humidity Range: 20% to 95% Rh) - 220-240 V 50/60 Hz |
| 51-CTC350500-10 | Climate Test Chamber 500 Liters (Temperature Range: -10°C / +60°C, Humidity Range: 20% to 95% Rh) - 220-240 V 50/60 Hz |
| 51-CTC350500-20 | Climate Test Chamber 500 Liters (Temperature Range: -20°C / +80°C, Humidity Range: 20% to 95% Rh) - 220-240 V 50/60 Hz |
| 51-CTC350500-40 | Climate Test Chamber 500 Liters (Temperature Range: -40°C / +60°C, Humidity Range: 20% to 95% Rh) - 220-240 V 50/60 Hz |
| 51-CTC350500-60 | Climate Test Chamber 500 Liters (Temperature Range: -60°C / +60°C, Humidity Range: 20% to 95% Rh) - 220-240 V 50/60 Hz |
| 51-CTC350120-10 | Climate Test Chamber 120 Liters (Temperature Range: -10°C / +60°C, Humidity Range: 20% to 95% Rh) - 220-240 V 50/60 Hz |
| 51-CTC350120-20 | Climate Test Chamber 120 Liters (Temperature Range: -20°C / +80°C, Humidity Range: 20% to 95% Rh) - 220-240 V 50/60 Hz |
| 51-CTC350120-40 | Climate Test Chamber 120 Liters (Temperature Range: -40°C / +60°C, Humidity Range: 20% to 95% Rh) - 220-240 V 50/60 Hz |
| 51-CTC350120-60 | Climate Test Chamber 120 Liters (Temperature Range: -60°C / +60°C, Humidity Range: 20% to 95% Rh) - 220-240 V 50/60 Hz |
| 51-CTC350250-10 | Climate Test Chamber 250 Liters (Temperature Range: -10°C / +60°C, Humidity Range: 20% to 95% Rh) - 220-240 V 50/60 Hz |
| 51-CTC350250-20 | Climate Test Chamber 250 Liters (Temperature Range: -20°C / +80°C, Humidity Range: 20% to 95% Rh) - 220-240 V 50/60 Hz |
| 51-CTC350250-40 | Climate Test Chamber 250 Liters (Temperature Range: -40°C / +60°C, Humidity Range: 20% to 95% Rh) - 220-240 V 50/60 Hz |
| 51-CTC350250-60 | Climate Test Chamber 250 Liters (Temperature Range: -60°C / +60°C, Humidity Range: 20% to 95% Rh) - 220-240 V 50/60 Hz |
| 51-CTC350500-10 | Climate Test Chamber 500 Liters (Temperature Range: -10°C / +60°C, Humidity Range: 20% to 95% Rh) - 220-240 V 50/60 Hz |
| 51-CTC350500-20 | Climate Test Chamber 500 Liters (Temperature Range: -20°C / +80°C, Humidity Range: 20% to 95% Rh) - 220-240 V 50/60 Hz |
| 51-CTC350500-40 | Climate Test Chamber 500 Liters (Temperature Range: -40°C / +60°C, Humidity Range: 20% to 95% Rh) - 220-240 V 50/60 Hz |
| 51-CTC350500-60 | Climate Test Chamber 500 Liters (Temperature Range: -60°C / +60°C, Humidity Range: 20% to 95% Rh) - 220-240 V 50/60 Hz |
The Climatic test chambers are environmental testing underwithin the temperature and humidity range specified by the user.
Climate Test Cabins are developed to simulate real enviromental conditions by controlling temperature, humidity and day & night lighting cycles.
By means of their wide temperature and humidity control range various kinds of tests could be performed in different areas. Stability, artificial aging and storage test can be easily done as well. The excellent design of test cabinets allows them to be used for different purposes in different sectors such as;
To ensure maximum durability and reliability, adequate materials were chosen fort he construction of the products. The chamber is made of Stainless Steel. The outer body is made of Epoxy coated Galvanic Steel to resist high humidity levels. The lights are located inside the door and protected with a glass window. There is an also internal glass door which allows controlling the samples without disturbing the temperature and humidity conditions inside the chambers.
The insulation becomes more important for the efficiency of the product when cold and hot temperatures are concerned. It is made of high density injected polyurethane.
The humidity is produced by the humidity generator and measured by a humidity sensor. The recovery time is fast and humidity measurement is sensitive. The heating function is controlled by PID while cooling and humidity are controlled by proportional system.
User friendly control panel includes 800x450 pixel display.
Powerful air circulation system maintains temperature and humidity uniformity and stability even at low temperatures.
Directional airflow assures quick recovery after door openings. The state-of-art control system is based on programmable microprocessor technology.
| 120 Liters Climatic Test Chambers | ||||
|---|---|---|---|---|
| Product Code | 51-CTC350120-10 | 51-CTC350120-20 | 51-CTC350120-40 | 51-CTC350120-60 |
| Volume | 120 Liters | 120 Liters | 120 Liters | 120 Liters |
| Temperature Range | -10°C / +60°C | -20°C / +80°C | -40°C / +100°C | -60°C / +150°C |
| Temperature Precision | ± 0,1 ° C | ± 0,1 ° C | ± 0,1 ° C | ± 0,1 ° C |
| Temperature Fluctuation | ± 2°C | ± 2°C | ± 2°C | ± 2°C |
| Temperature Uniformity | ± 2°C | ± 2°C | ± 2°C | ± 2°C |
| Humidity Range | 20% to 95% Rh | 20% to 95% Rh | 20% to 95% Rh | 20% to 95% Rh |
| Humidity Precision | ± 0,1 Rh | ± 0,1 Rh | ± 0,1 Rh | ± 0,1 Rh |
| Humidity Fluctuation | ± 5 Rh | ± 5 Rh | ± 5 Rh | ± 5 Rh |
| Humidity Uniformity | ± 2 Rh | ± 2 Rh | ± 2 Rh | ± 2 Rh |
| Maximum Light Intensity | 6000 to 12000 Lux | 6000 to 12000 Lux | 6000 to 12000 Lux | 6000 to 12000 Lux |
| Internal Dimensions | 400x500x600 mm | 400x500x600 mm | 400x500x600 mm | 400x500x600 mm |
| External Dimensions | 650x700x1200 mm | 650x700x1300 mm | 650x750x1350 mm | 650x800x1450 mm |
| Weight(Approx) | 130 kg | 140 kg | 150 kg | 170 kg |
| Power | 220-240 V 50/60 Hz | 220-240 V 50/60 Hz | 220-240 V 50/60 Hz | 220-240 V 50/60 Hz |
| 250 Liters Climatic Test Chambers | ||||
| Product Code | 51-CTC476250-10 | 51-CTC476250-20 | 51-CTC476250-40 | 51-CTC476250-60 |
| Volume | 250 Liters | 250 Liters | 250 Liters | 250 Liters |
| Temperature Range | -10°C / +60°C | -20°C / +80°C | -40°C / +100°C | -60°C / +150°C |
| Temperature Precision | ± 0,1 ° C | ± 0,1 ° C | ± 0,1 ° C | ± 0,1 ° C |
| Temperature Fluctuation | ± 2°C | ± 2°C | ± 2°C | ± 2°C |
| Temperature Uniformity | ± 2°C | ± 2°C | ± 2°C | ± 2°C |
| Humidity Range | 20% to 95% Rh | 20% to 95% Rh | 20% to 95% Rh | 20% to 95% Rh |
| Humidity Precision | ± 0,1 Rh | ± 0,1 Rh | ± 0,1 Rh | ± 0,1 Rh |
| Humidity Fluctuation | ± 5 Rh | ± 5 Rh | ± 5 Rh | ± 5 Rh |
| Humidity Uniformity | ± 2 Rh | ± 2 Rh | ± 2 Rh | ± 2 Rh |
| Maximum Light Intensity | 6000 to 12000 Lux | 6000 to 12000 Lux | 6000 to 12000 Lux | 6000 to 12000 Lux |
| Internal Dimensions | 500x600x850 mm | 500x600x850 mm | 500x600x850 mm | 500x600x850 mm |
| External Dimensions | 700x720x1700 mm | 750x770x1800 mm | 750x770x1850 mm | 800x820x1950 mm |
| Weight(Approx) | 160 kg | 180 kg | 190 kg | 210 kg |
| Power | 220-240 V 50/60 Hz | 220-240 V 50/60 Hz | 220-240 V 50/60 Hz | 220-240 V 50/60 Hz |
| 500 Liters Climatic Test Chambers | ||||
| Product Code | 51-CTC476500-10 | 51-CTC476500-20 | 51-CTC476500-40 | 51-CTC476500-60 |
| Volume | 500 Liters | 500 Liters | 500 Liters | 500 Liters |
| Temperature Range | -10°C / +60°C | -20°C / +80°C | -40°C / +100°C | -60°C / +150°C |
| Temperature Precision | ± 0,1 ° C | ± 0,1 ° C | ± 0,1 ° C | ± 0,1 ° C |
| Temperature Fluctuation | ± 2°C | ± 2°C | ± 2°C | ± 2°C |
| Temperature Uniformity | ± 2°C | ± 2°C | ± 2°C | ± 2°C |
| Humidity Range | 20% to 95% Rh | 20% to 95% Rh | 20% to 95% Rh | 20% to 95% Rh |
| Humidity Precision | ± 0,1 Rh | ± 0,1 Rh | ± 0,1 Rh | ± 0,1 Rh |
| Humidity Fluctuation | ± 5 Rh | ± 5 Rh | ± 5 Rh | ± 5 Rh |
| Humidity Uniformity | ± 2 Rh | ± 2 Rh | ± 2 Rh | ± 2 Rh |
| Maximum Light Intensity | 6000 to 12000 Lux | 6000 to 12000 Lux | 6000 to 12000 Lux | 6000 to 12000 Lux |
| Internal Dimensions | 780x700x920 mm | 780x700x920 mm | 780x700x920 mm | 780x700x920 mm |
| External Dimensions | 1350x950x1850 mm | 750x770x1900 mm | 1400x1000x1950 mm | 1450x1050x2000 mm |
| Weight(Approx) | 220 kg | 240 kg | 260 kg | 280 kg |
| Power | 220-240 V 50/60 Hz | 220-240 V 50/60 Hz | 220-240 V 50/60 Hz | 220-240 V 50/60 Hz |