VICAT TEST APPARATUS

Vicat Test Apparatus Vicat Test Apparatus Vicat Test Apparatus

VICAT TEST APPARATUS

50-VA473700 Vicat Test Apparatus, EN Standards
50-VA473705 Vicat Test Apparatus, ASTM Standards
ORIGIN: TÜRKİYE
Standards: ASTM C187, C191 | AASHTO T131 | EN 196-3:2005 | EN 408-2
50-VA473700 Vicat Test Apparatus, EN Standards
50-VA473705 Vicat Test Apparatus, ASTM Standards
ORIGIN: TÜRKİYE
Standards: ASTM C187, C191 | AASHTO T131 | EN 196-3:2005 | EN 408-2

VICAT TEST APPARATUS

The Vicat Test Apparatus is used to determine the amount of water required to produce a cement paste of standard consistency and the setting time.

The frame is supplied complete with a 300 g consistency plunger (dia. 10 mm). The measurement of the movement is given by an indicator which moves along a scale graduated in millimetres.

The apparatus is supplied complete with glass plate , ASTM or EN Standard Needle and mould.

The 50-VA473700 Model EN Standards Vicat Test Set is supplied complete with;
• Vicat Frame
• Consistency Plunger
• Additiniol Weight, 700 gr, EN
• Vicat Mould (EN Standard), Base: 80 mm, Top: 70 mm, Height: 40 mm
• Initial Vicat Needle (EN Standard), Diameter: 1.13 mm
• Final Vicat Needle, 1.13 mm diameter, EN Standard
• Supporting Plate
• Glass Thermometer 110°C
• Transfer Dish

The 50-VA473705 Model ASTM Standards Vicat Test Set is supplied complete with;
• Vicat Frame
• Consistency Plunger
• Additiniol Weight, 700 gr, EN
• Vicat Mould (ASTM Standard), Base: 70 mm, Top: 60 mm, Height: 40 mm
• Vicat Needle (ASTM Standard), Diameter: 1 mm
• Supporting Plate
• Glass Thermometer 110°C
• Transfer Dish

Accessories:
• 50-VAP473800 / Vicat Frame
• 50-VAP473802 / Consistency Plunger 10 mm diameter
• 50-VAP473804 / Additiniol Weight, 700 gr, EN
• 50-VAP473806 / Vicat Mould (EN Standard), Base: 80 mm, Top: 70 mm, Height: 40 mm
• 50-VAP473808 / Vicat Mould (ASTM Standard), Base: 70 mm, Top: 60 mm, Height: 40 mm
• 50-VAP473810 / Initial Vicat Needle (EN Standard), Diameter: 1.13 mm
• 50-VAP473812 / Final Vicat Needle, 1.13 mm diameter, EN Standard
• 50-VAP473814 / Vicat Needle (ASTM Standard), Diameter: 1 mm
• 50-VAP473816 / Glass Base Plate
• 50-VAP473820 / Thermometer Glass -10°C / + 50°C
• 50-VAP473826 / Transfer Dish

Technical Specifications for VICAT TEST APPARATUS

Dimensions 260x250x450 mm
Weight (approx) 4 kg

ACCESSORIES AND SPARE PARTS FOR VICAT TEST APPARATUS

50-VAP473800 Vicat Frame
50-VAP473802 Consistency Plunger 10 mm diameter
50-VAP473804 Additiniol Weight, 700 gr, EN
50-VAP473806 Vicat Mould (EN Standard), Base: 80 mm, Top: 70 mm, Height: 40 mm
50-VAP473808 Vicat Mould (ASTM Standard), Base: 70 mm, Top: 60 mm, Height: 40 mm
50-VAP473810 Initial Vicat Needle (EN Standard), Diameter: 1.13 mm
50-VAP473812 Final Vicat Needle, 1.13 mm diameter, EN Standard
50-VAP473814 Vicat Needle (ASTM Standard), Diameter: 1 mm
50-VAP473816 Glass Base Plate
50-VAP473820 Thermometer Glass -10°C / + 50°C
50-VAP473826 Transfer Dish

DATASHEET VICAT TEST APPARATUS

VICAT TEST APPARATUS

VICAT TEST APPARATUS VICAT TEST APPARATUS The Vicat Test Apparatus is used to determine the amount of water required to produce a cement paste of standard consistency and the setting time. 50-VA473700
$ 125.00 In stock