VICAT TEST APPARATUS

Vicat Test Apparatus Vicat Test Apparatus Vicat Test Apparatus

VICAT TEST APPARATUS

50-VA473700 Vicat Test Apparatus, EN Standards
50-VA473705 Vicat Test Apparatus, ASTM Standards
ORIGIN: TÜRKİYE
Standards: ASTM C187, C191 | AASHTO T131 | EN 196-3:2005 | EN 408-2
50-VA473700 Vicat Test Apparatus, EN Standards
50-VA473705 Vicat Test Apparatus, ASTM Standards
ORIGIN: TÜRKİYE
Standards: ASTM C187, C191 | AASHTO T131 | EN 196-3:2005 | EN 408-2
VICAT TEST APPARATUS

VICAT TEST APPARATUS

The Vicat Test Apparatus is used to determine the amount of water required to produce a cement paste of standard consistency and the setting time.

The frame is supplied complete with a 300 g consistency plunger (dia. 10 mm). The measurement of the movement is given by an indicator which moves along a scale graduated in millimetres.

The apparatus is supplied complete with glass plate , ASTM or EN Standard Needle and mould.

The 50-VA473700 Model EN Standards Vicat Test Set is supplied complete with;
• Vicat Frame
• Consistency Plunger
• Additiniol Weight, 700 gr, EN
• Vicat Mould (EN Standard), Base: 80 mm, Top: 70 mm, Height: 40 mm
• Initial Vicat Needle (EN Standard), Diameter: 1.13 mm
• Final Vicat Needle, 1.13 mm diameter, EN Standard
• Supporting Plate
• Glass Thermometer 110°C
• Transfer Dish

The 50-VA473705 Model ASTM Standards Vicat Test Set is supplied complete with;
• Vicat Frame
• Consistency Plunger
• Additiniol Weight, 700 gr, EN
• Vicat Mould (ASTM Standard), Base: 70 mm, Top: 60 mm, Height: 40 mm
• Vicat Needle (ASTM Standard), Diameter: 1 mm
• Supporting Plate
• Glass Thermometer 110°C
• Transfer Dish

Accessories:
• 50-VAP473800 / Vicat Frame
• 50-VAP473802 / Consistency Plunger 10 mm diameter
• 50-VAP473804 / Additiniol Weight, 700 gr, EN
• 50-VAP473806 / Vicat Mould (EN Standard), Base: 80 mm, Top: 70 mm, Height: 40 mm
• 50-VAP473808 / Vicat Mould (ASTM Standard), Base: 70 mm, Top: 60 mm, Height: 40 mm
• 50-VAP473810 / Initial Vicat Needle (EN Standard), Diameter: 1.13 mm
• 50-VAP473812 / Final Vicat Needle, 1.13 mm diameter, EN Standard
• 50-VAP473814 / Vicat Needle (ASTM Standard), Diameter: 1 mm
• 50-VAP473816 / Glass Base Plate
• 50-VAP473820 / Thermometer Glass -10°C / + 50°C
• 50-VAP473826 / Transfer Dish

Technical Specifications for VICAT TEST APPARATUS

Dimensions 260x250x450 mm
Weight (approx) 4 kg

ACCESSORIES AND SPARE PARTS FOR VICAT TEST APPARATUS

50-VAP473800 Vicat Frame
50-VAP473802 Consistency Plunger 10 mm diameter
50-VAP473804 Additiniol Weight, 700 gr, EN
50-VAP473806 Vicat Mould (EN Standard), Base: 80 mm, Top: 70 mm, Height: 40 mm
50-VAP473808 Vicat Mould (ASTM Standard), Base: 70 mm, Top: 60 mm, Height: 40 mm
50-VAP473810 Initial Vicat Needle (EN Standard), Diameter: 1.13 mm
50-VAP473812 Final Vicat Needle, 1.13 mm diameter, EN Standard
50-VAP473814 Vicat Needle (ASTM Standard), Diameter: 1 mm
50-VAP473816 Glass Base Plate
50-VAP473820 Thermometer Glass -10°C / + 50°C
50-VAP473826 Transfer Dish

VICAT TEST APPARATUS VICAT TEST APPARATUS The Vicat Test Apparatus is used to determine the amount of water required to produce a cement paste of standard consistency and the setting time. 50-VA473700
$ 125.00 In stock